[{"data":1,"prerenderedAt":85},["ShallowReactive",2],{"formation-se-former-a-la-thermographie-infrarouge-module-2":3},{"title":4,"slug":7,"alsoIn":8,"duration":10,"goal":12,"note":15,"summary":18,"challenges":21,"objectives":28,"program":41,"audience":60,"prerequisites":67,"modalities":74,"assessment":78,"regulatoryScope":82},{"fr":5,"en":6},"Se former à la thermographie infrarouge (module 2)","Training in infrared thermography (module 2)","se-former-a-la-thermographie-infrarouge-module-2",[9],"incendie",{"fr":11,"en":11},"3 Jours",{"fr":13,"en":14},"Analyser une situation de mesure dans le domaine électrique","Analyse a measurement situation in the electrical field",{"fr":16,"en":17},"Modalité : Présentiel. Programme et prérequis sur demande.","Format: Présentiel. Programme and prerequisites on request.",{"fr":19,"en":20},"Le second module de la filière : passer de la prise de mesure à l'analyse, en appliquant la thermographie aux installations électriques.","The second module of the pathway: moving from measurement to analysis, applying thermography to electrical installations.",[22,25],{"fr":23,"en":24},"Un point chaud ne dit rien tant qu'on ne l'a pas rapporté à la charge et à l'environnement.","A hot spot says nothing until it is related to the load and the environment.",{"fr":26,"en":27},"Deux anomalies d'aspect identique peuvent appeler des décisions opposées.","Two anomalies that look identical can call for opposite decisions.",[29,32,35,38],{"fr":30,"en":31},"Analyser un thermogramme d'installation électrique dans son contexte d'exploitation.","Analyse a thermogram of an electrical installation in its operating context.",{"fr":33,"en":34},"Relier un échauffement observé à sa cause probable.","Relate observed heating to its probable cause.",{"fr":36,"en":37},"Évaluer la gravité d'une anomalie et la suite à donner.","Assess the severity of an anomaly and the action it calls for.",{"fr":39,"en":40},"Structurer un compte rendu de campagne.","Structure a campaign report.",[42,45,48,51,54,57],{"fr":43,"en":44},"Échauffements dans les installations électriques : causes et mécanismes.","Heating in electrical installations: causes and mechanisms.",{"fr":46,"en":47},"Influence de la charge, de la ventilation et de l'environnement.","Influence of load, ventilation and environment.",{"fr":49,"en":50},"Méthode d'analyse d'un thermogramme et cas d'interprétation.","Method for analysing a thermogram, with interpretation cases.",{"fr":52,"en":53},"Évaluation de la gravité et hiérarchisation des suites.","Severity assessment and prioritisation of follow-up.",{"fr":55,"en":56},"Structure et rédaction d'un compte rendu.","Structure and drafting of a report.",{"fr":58,"en":59},"Travaux pratiques d'analyse sur cas réels.","Hands-on analysis exercises on real cases.",[61,64],{"fr":62,"en":63},"Techniciens ayant suivi le module 1 de thermographie","Technicians who have completed thermography module 1",{"fr":65,"en":66},"Personnel de maintenance électrique","Electrical maintenance staff",[68,71],{"fr":69,"en":70},"Avoir suivi le module 1 de thermographie infrarouge ou disposer d'une pratique équivalente.","Have completed infrared thermography module 1 or have equivalent practical experience.",{"fr":72,"en":73},"Connaissances en électricité correspondant aux installations analysées.","Electrical knowledge matching the installations analysed.",[75],{"fr":76,"en":77},"Présentiel : études de cas réels, analyses guidées et travaux pratiques.","In person: real case studies, guided analysis and hands-on work.",[79],{"fr":80,"en":81},"Évaluation des acquis par analyse de thermogrammes et rédaction d'un compte rendu.","Assessment through thermogram analysis and report writing.",{"fr":83,"en":84},"Ce module approfondit l'analyse en domaine électrique. La délivrance de comptes rendus relevant du référentiel APSAD D19 suppose la qualification correspondante.","This module deepens analysis in the electrical field. Issuing reports under the APSAD D19 standard requires the corresponding qualification.",1793204933271]